Pdr58, Pdr59 – Dell PowerEdge VRTX User Manual
Page 457

PDR58
Message
arg1
is incompatible.
Arguments
•
arg1 =
PD Name
Detailed
Description
A user attempted to replace a disk with another disk that is using an incompatible technology.
For example, replaced one side of a mirror with a SAS disk when the other side of the mirror is
using SATA technology.
Recommended
Response Action
Refer to the hardware documentation for information on replacing disks.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR59
Message
A bad disk block was reassigned on
arg1
.
Arguments
•
arg1 =
physical disk
Detailed
Description
The disk has a bad block. Data was remapped to another disk block. No data loss has
occurred.
Recommended
Response Action
Monitor the disk for other messages or indications of poor health.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 3 (Informational)
Trap/EventID
4347
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
457