Pdr3, Pdr4 – Dell PowerEdge VRTX User Manual
Page 428
![background image](/manuals/620821/428/background.png)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR3
Message
arg1
is not functioning correctly.
Arguments
•
arg1 =
PD Name
Detailed
Description
The RAID Controller may not be able to read/write data to the physical disk drive indicated in
the message. This may be due to a failure with the physical disk drive or because the physical
disk drive was removed from the system.
Recommended
Response Action
Remove and re-insert the physical disk drive identified in the message and make sure the
physical disk drive is inserted properly. If the issue persists, replace the physical disk drive.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR4
Message
arg1
returned to a ready state.
Arguments
•
arg1 =
physical disk
Detailed
Description
A physical drive that was previously in an error state has returned to a ready state.
Recommended
Response Action
No response action is required.
Category
Storage
428