Vdr50 – Dell PowerEdge VRTX User Manual
Page 883
Arguments
•
arg1 =
VD Name
Detailed
Description
A redundant virtual disk has lost redundancy. This may occur when the virtual disk suffers the
failure of more than one physical disk. In this case, both the source physical disk and the target
disk with redundant data have failed. A rebuild is not possible because there is no longer
redundancy.
Recommended
Response Action
Replace the failed disks and restore from backup.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 1 (Critical)
Trap/EventID
4353
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
VDR50
Message
Background Initialization (BGI) completed with uncorrectable errors on
arg1
.
Arguments
•
arg1 =
virtual disk
Detailed
Description
The background initialization task encountered errors that cannot be corrected. The virtual
disk contains physical disks that have unusable disk space or disk errors that cannot be
corrected.
Recommended
Response Action
Review other messages to identify whether the physical disk that has errors. If the virtual disk
is redundant, you can replace the physical disk and continue using the virtual disk. If the virtual
disk is non-redundant, you need to recreate the virtual disk after replacing the physical disk.
After replacing the physical disk, run a consistency check to verify the data.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 1 (Critical)
Trap/EventID
4353
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
883