Enc25, Enc26 – Dell PowerEdge VRTX User Manual
Page 224
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC25
Message
arg1
has a hardware error.
Arguments
•
arg1 =
enclosure name
Detailed
Description
The enclosure or an enclosure component is in a Failed or Degraded state.
Recommended
Response Action
Verify the health of the enclosure and its components. See the storage hardware
documentation for more information. Contact technical support.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC26
Message
arg1
is not responding.
Arguments
•
arg1 =
enclosure name
Detailed
Description
The enclosure or an enclosure component is in a Failed or Degraded state. It is not responding
to storage management commands or there is a connectivity problem between the controller
and enclosure.
Recommended
Response Action
Verify the health of the enclosure and its components. See the hardware documentation to for
more information. Contact technical support.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
224