Pdr47, Pdr48 – Dell PowerEdge VRTX User Manual
Page 451

Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR47
Message
A block on
arg1
was punctured by the controller.
Arguments
•
arg1 =
physical disk
Detailed
Description
The controller encountered an unrecoverable medium error when attempting to read a block
on the physical disk and marked that block as invalid. If the controller encountered the
unrecoverable medium error on a source physical disk during a rebuild or reconfigure
operation, it punctures the corresponding block on the target physical disk. The invalid block
clears on a write operation.
Recommended
Response Action
Back up the data from the disk. Start disk initialization and wait for it to complete, and then
restore the data from a backup copy.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR48
Message
The
arg1
rebuild has resumed.
Arguments
•
arg1 =
physical disk
Detailed
Description
This message is generated after rebuild resumes on a physical disk.
Recommended
Response Action
No response action is required.