Rdu8507, Rdu8508 – Dell PowerEdge VRTX User Manual
Page 627

Category
Audit
SubCategory
RDU = Redundancy
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
RDU8507
Message
CMC
arg1
: disable failover
Arguments
•
arg1 =
slot number
Detailed
Description
CMC failover is disabled.
Recommended
Response Action
No response action is required.
Category
Audit
SubCategory
RDU = Redundancy
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
RDU8508
Message
CMC
arg1
: cannot failback since the other CMC is non-functional.
Arguments
•
arg1 =
slot number
Detailed
Description
For failover to occur, the standby CMC needs to be present, at the same version as the primary
and healthy. During failover, the active CMC resets and the standby CMC becomes active. This
message is logged when the standby CMC is absent, unhealthy or at a different firmware
version.
627