Fan0000, Fan0001 – Dell PowerEdge VRTX User Manual
Page 232

LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FAN0000
Message
Fan
arg1
RPM is less than the lower warning threshold.
Arguments
•
arg1 =
number
Detailed
Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended
Response Action
Remove and re-install the fan at the next scheduled service window. If the issue persists,
contact technical support. Refer to the product documentation to choose a convenient contact
method.
Category
System Health
SubCategory
FAN = Fan Event
Severity
Severity 2 (Warning)
Trap/EventID
2154
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
FAN0001
Message
Fan
arg1
RPM is less than the lower critical threshold.
Arguments
•
arg1 =
number
Detailed
Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended
Response Action
Remove and re-install the fan. If the issue persists, contact technical support. Refer to the
product documentation to choose a convenient contact method.
Category
System Health
SubCategory
FAN = Fan Event
232