LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FAN0000

Message

Fan

arg1

RPM is less than the lower warning threshold.

Arguments

arg1 =

number

Detailed
Description

The fan is not performing optimally. The fan may be installed improperly or may be failing.

Recommended
Response Action

Remove and re-install the fan at the next scheduled service window. If the issue persists,
contact technical support. Refer to the product documentation to choose a convenient contact
method.

Category

System Health

SubCategory

FAN = Fan Event

Severity

Severity 2 (Warning)

Trap/EventID

2154

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

FAN0001

Message

Fan

arg1

RPM is less than the lower critical threshold.

Arguments

arg1 =

number

Detailed
Description

The fan is not performing optimally. The fan may be installed improperly or may be failing.

Recommended
Response Action

Remove and re-install the fan. If the issue persists, contact technical support. Refer to the
product documentation to choose a convenient contact method.

Category

System Health

SubCategory

FAN = Fan Event