beautypg.com

Tmp0132, Tmp0133 – Dell PowerEdge VRTX User Manual

Page 843

background image

Category

System Health

SubCategory

TMP = Temperature

Severity

Severity 1 (Critical)

Trap/EventID

2161

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

TMP0132

Message

The control panel temperature is greater than the upper warning threshold.

Detailed
Description

Ambient air temperature is too warm or one or more fans may have failed.

Recommended
Response Action

Check system operating environment and review event log for fan failures.

Category

System Health

SubCategory

TMP = Temperature

Severity

Severity 2 (Warning)

Trap/EventID

2162

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

TMP0133

Message

The control panel temperature is greater than the upper critical threshold.

Detailed
Description

Ambient air temperature is too warm or one or more fans may have failed.

Recommended
Response Action

Check system operating environment and review event log for fan failures.

Category

System Health

SubCategory

TMP = Temperature

Severity

Severity 1 (Critical)

843