beautypg.com

Cmc8512, Cmc8513 – Dell PowerEdge VRTX User Manual

Page 111

background image

CMC8512

Message

The Extended Storage feature activation timed out. The feature is not active.

Detailed
Description

The Extended Storage feature is not activated if the removable flash media SD card on the
secondary CMC does not respond within 90 seconds after activation is initiated.

Recommended
Response Action

Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller
> Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If
errors are displayed, execute the following racadm command: "racadm cmcchangover". 3)
Repair the removable flash media SD Card by selecting the Chassis Controller > Flash Media >
Configuration > Repair Active Controller Media in the CMC Web interface. Repairing is only
allowed on the SD card of the primary CMC. If the problem persists, replace the card.

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

8689

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8513

Message

The Extended Storage feature activation on the secondary CMC timed out. The feature is being
returned to single CMC mode.

Detailed
Description

The Extended Storage feaure activtion on the secondary CMC timed out. If the media on
Standby CMC doesnt respond within 90 seconds of confirming activation the feature returns to
single CMC mode.

Recommended
Response Action

Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller
> Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If
errors are displayed, execute the following racadm command: "racadm cmcchangover". 3)
Repair the removable flash media SD Card by selecting the Chassis Controller > Flash Media >
Configuration > Repair Active Controller Media in the CMC Web interface. Repairing is only
allowed on the SD card of the primary CMC. If the problem persists, replace the card.

Category

Audit

SubCategory

CMC = Chassis Management Controller

Severity

Severity 2 (Warning)

Trap/EventID

8690

LCD Message

No LCD message display defined.

111