beautypg.com

Iov107 – Dell PowerEdge VRTX User Manual

Page 299

background image

Detailed
Description

The Chassis manager is unable to power on adapter. Possible reasons for power failures are:
1. Adapter not a approved by Dell and therefore not within require specifications 2. Adpater not
fully inserted in the slot 3. Auxiliary power cable not connected (applicable to slot 1 - 3 only) 4,
Adapter is damaged

Recommended
Response Action

Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For
a list of supported devices, contact the service provider.

Category

System Health

SubCategory

IOV = IO Virtualization

Severity

Severity 2 (Warning)

Trap/EventID

2554

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LCD;#LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

IOV107

Message

PCIe slot

arg1

adapter

arg2

removed while powered on.

Arguments

arg1 =

adapter slot number

arg2 =

device ID

Detailed
Description

The Chassis manager has detected the removal of a PCIe adapter card which was assigned to
a powered on server.

Recommended
Response Action

Power down the affected server(s) and then power on the server(s). Note: OS reboot will not
correct this issue.

Category

System Health

SubCategory

IOV = IO Virtualization

Severity

Severity 1 (Critical)

Trap/EventID

2553

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LCD;#LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

299