beautypg.com

Psu0032 – Dell PowerEdge VRTX User Manual

Page 539

background image

Arguments

arg1 =

number

Detailed
Description

Status from the power supply indicates a power supply exception occurred. The power supply
will try to operate. System Performance and power redundancy may be degraded or lost.

Recommended
Response Action

Remove input power and re-install supply at the next service window.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PSU0032

Message

The temperature for power supply

arg1

is in a warning range.

Arguments

arg1 =

number

Detailed
Description

System performance may be degraded.

Recommended
Response Action

Check the system operating environment, including airflow and inlet temperature. Check
system logs for temperature and thermal component failures.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 2 (Warning)

Trap/EventID

2186

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

539