Rdu0011, Rdu0012 – Dell PowerEdge VRTX User Manual
Page 639

Detailed
Description
One of more fans have failed or have been removed or a configuration change occurred which
requires additional fans.
Recommended
Response Action
Remove and re-install failed fans or install additional fans.
Category
System Health
SubCategory
RDU = Redundancy
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
RDU0011
Message
The power supplies are redundant.
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category
System Health
SubCategory
RDU = Redundancy
Severity
Severity 3 (Informational)
Trap/EventID
2475
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
RDU0012
Message
Power supply redundancy is lost.
Detailed
Description
The current power operational mode is non-redundant because of a power supply exception, a
power supply inventory change, or a system power inventory change. The system was
previously operating in a power redundant mode.
639