Cpu0003, Cpu0004 – Dell PowerEdge VRTX User Manual
Page 141

SubCategory
CPU = Processor
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
CPU0003
Message
CPU
arg1
is stuck in POST.
Arguments
•
arg1 =
number
Detailed
Description
None
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Reduce system configuration to minimum memory and remove all PCI devices. If
system completes POST, update system BIOS. Re-install memory and PCI one component at a
time to meet the original configuration. 3) If the issue still persists, contact technical support.
Refer to the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
CPU = Processor
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
CPU0004
Message
CPU
arg1
failed to initialize.
Arguments
•
arg1 =
number
Detailed
Description
None
141