Amp0320, Amp0321, Amp0322 – Dell PowerEdge VRTX User Manual
Page 57

AMP0320
Message
Chassis power level current is greater than the upper warning threshold.
Detailed
Description
Product documentation contains information on correct configuration. The failure could also
be caused by a faulty component or related cabling. System performance may be degraded.
Recommended
Response Action
Review system power policy, check system logs for power related failures, and review system
configuration changes
Category
System Health
SubCategory
AMP = Amperage
Severity
Severity 2 (Warning)
Trap/EventID
2178
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
AMP0321
Message
Chassis power level current is greater than the upper critical threshold.
Detailed
Description
Product documentation contains information on correct configuration. The failure could also
be caused by a faulty component or related cabling. System performance may be degraded.
Recommended
Response Action
Review system power policy, check system logs for power related failures, and review system
configuration changes
Category
System Health
SubCategory
AMP = Amperage
Severity
Severity 1 (Critical)
Trap/EventID
2177
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
AMP0322
Message
Chassis power level current is outside of range.