beautypg.com

Vdr51, Vdr52 – Dell PowerEdge VRTX User Manual

Page 884

background image

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR51

Message

The consistency check process made corrections and completed on

arg1

.

Arguments

arg1 =

virtual disk

Detailed
Description

The consistency check completed on the virtual disk after making corrections.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 3 (Informational)

Trap/EventID

4355

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

VDR52

Message

The consistency check found inconsistent parity data on

arg1

.

Arguments

arg1 =

virtual disk

Detailed
Description

The data on physical disk members of the virtual disk does not match. Redundancy may be lost.

Recommended
Response Action

Rerun the consistency check task. If you receive this message again, verify the health of the
physical disks included in the virtual disk. See the storage hardware documentation for more
information. Review messages for significant messages related to the physical disks. If a
physical disk has a problem, replace it and restore from a backup copy. Contact technical
support if the issue persists.

Category

Storage

SubCategory

VDR = Virtual Disk

Severity

Severity 2 (Warning)

884