Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
CTL44
Message
Diagnostic message
arg1
from
arg2
Arguments
•
arg1 =
message
•
arg2 =
Controller name
Detailed
Description
A diagnostics test failed. The text for this message is generated by the tool that ran the
diagnostics and can vary depending on the situation.
Recommended
Response Action
Refer to the storage hardware documentation for more information on the diagnostic test.
Category
Storage
SubCategory
CTL = Storage Contr
Severity
Severity 1 (Critical)
Trap/EventID
4329
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
CTL45
Message
Single-bit ECC error on
arg1
.
Arguments
•
arg1 =
Controller name
Detailed
Description
The Dual In-line Memory Module (DIMM) is beginning to malfunction.
Recommended
Response Action
Replace the Dual In-line Memory Module (DIMM) to avoid data loss or data corruption. The
DIMM is a part of the controller battery pack. Refer to hardware documentation for information
on replacing the DIMM.
Category
Storage
SubCategory
CTL = Storage Contr
Severity
Severity 2 (Warning)
Trap/EventID
4330