Cmc8525, Cmc8526 – Dell PowerEdge VRTX User Manual
Page 117
![background image](/manuals/620821/117/background.png)
Detailed
Description
The Mezz card 4 FRU for the server specified in the message is not functioning or CMC is
unable to read it.
Recommended
Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset
CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
2545
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
CMC8525
Message
The FRU on the sleeve
arg1
is not functioning.
Arguments
•
arg1 =
slot number
Detailed
Description
The FRU on the sleeve specified in the message is not functioning or CMC is unable to read it.
Recommended
Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset
CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
2545
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
CMC8526
Message
Unable to retrieve the server-
arg1
CPU information.
Arguments
•
arg1 =
slot number
117