Rdu8509, Rdu8510 – Dell PowerEdge VRTX User Manual
Page 628

Recommended
Response Action
Check the status of the standby CMC and make sure the firmware version matches the primary
CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service
provider.
Category
Audit
SubCategory
RDU = Redundancy
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
RDU8509
Message
CMC
arg1
: cannot failover, chassis is in non-redundant state
Arguments
•
arg1 =
slot number
Detailed
Description
For failover to occur, the standby CMC needs to be present, at the same version as the primary
and healthy. During failover, the active CMC resets and the standby CMC becomes active. This
message is logged when the standby CMC is absent, unhealthy or at a different firmware
version.
Recommended
Response Action
Check the status of the standby CMC and make sure the firmware version matches the primary
CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service
provider.
Category
Audit
SubCategory
RDU = Redundancy
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
RDU8510
Message
CMC
arg1
: cannot failover, CMC firmware versions are different
628