beautypg.com

Rdu8509, Rdu8510 – Dell PowerEdge VRTX User Manual

Page 628

background image

Recommended
Response Action

Check the status of the standby CMC and make sure the firmware version matches the primary
CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service
provider.

Category

Audit

SubCategory

RDU = Redundancy

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

RDU8509

Message

CMC

arg1

: cannot failover, chassis is in non-redundant state

Arguments

arg1 =

slot number

Detailed
Description

For failover to occur, the standby CMC needs to be present, at the same version as the primary
and healthy. During failover, the active CMC resets and the standby CMC becomes active. This
message is logged when the standby CMC is absent, unhealthy or at a different firmware
version.

Recommended
Response Action

Check the status of the standby CMC and make sure the firmware version matches the primary
CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service
provider.

Category

Audit

SubCategory

RDU = Redundancy

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

RDU8510

Message

CMC

arg1

: cannot failover, CMC firmware versions are different

628