background image

Severity

Severity 3 (Informational)

Trap/EventID

2187

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0033

Message

The temperature for power supply

arg1

is outside of range.

Arguments

arg1 =

number

Detailed
Description

System performance may be degraded.

Recommended
Response Action

Check the system operating environment, including airflow and inlet temperature. Check
system logs for temperature and thermal component failures.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

2185

LCD Message

PSU temperature outside of range. Check PSU

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0034

Message

An under voltage fault detected on power supply

arg1

.

Arguments

arg1 =

number

Detailed
Description

This failure may be the result of an electrical issue with cables or subsystem components in
the system.

Recommended
Response Action

1) Remove and re-install the power supply. 2) Check cables and subsystem components in the
system for damage. 3) If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.

529