Psu0033, Psu0034 – Dell PowerEdge VRTX User Manual
Page 529

Severity
Severity 3 (Informational)
Trap/EventID
2187
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PSU0033
Message
The temperature for power supply
arg1
is outside of range.
Arguments
•
arg1 =
number
Detailed
Description
System performance may be degraded.
Recommended
Response Action
Check the system operating environment, including airflow and inlet temperature. Check
system logs for temperature and thermal component failures.
Category
System Health
SubCategory
PSU = Power Supply
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
PSU
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PSU0034
Message
An under voltage fault detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
This failure may be the result of an electrical issue with cables or subsystem components in
the system.
Recommended
Response Action
1) Remove and re-install the power supply. 2) Check cables and subsystem components in the
system for damage. 3) If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
529