Stor event messages, Stor1, Stor2 – Dell PowerEdge VRTX User Manual
Page 713: 39 stor event messages
![background image](/manuals/620821/713/background.png)
39
STOR Event Messages
STOR1
Message
A device
arg1
is in an unknown state.
Arguments
•
arg1 =
device name
Detailed
Description
The controller cannot communicate with a device. The state of the device cannot be
determined. There may be a bad or loose cable, or a missing device, or a problem with the
driver or firmware.
Recommended
Response Action
See the storage hardware documentation for information on checking the cables. Check for
problems with any enclosures attached to the system. Verify that the controller has a
supported version of the driver and firmware. Rebooting the system may resolve this problem.
Category
Storage
SubCategory
STOR = Storage
Severity
Severity 2 (Warning)
Trap/EventID
4178
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
STOR2
Message
SCSI sense data
arg1
.
Arguments
•
arg1 =
args
Detailed
Description
A SCSI device experienced an error, but may have recovered.
Recommended
Response Action
No response action is required.
Category
Storage
SubCategory
STOR = Storage
713