beautypg.com

Cmc8519, Cmc8520 – Dell PowerEdge VRTX User Manual

Page 114

background image

Recommended
Response Action

Do the following: 1) Remove the server identified in the message. 2) Restart the CMC and wait
for the CMC to complete the start up process. 3) Reinsert the server identified in the message.
If the problem persists, contact your service provider.

Category

System Health

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

2545

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8519

Message

The LOM riser FRU for slot

arg1

FRU ID

arg2

is not functioning.

Arguments

arg1 =

slot number

arg2 =

fru id

Detailed
Description

FRU of the LOM riser specified in the message is not functioning or CMC is unable to read it.

Recommended
Response Action

Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset
CMC and wait for a few minutes. If the issue persists, contact your service provider.

Category

System Health

SubCategory

CMC = Chassis Management Controller

Severity

Severity 1 (Critical)

Trap/EventID

2545

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

CMC8520

Message

The FRU on server

arg1

is not functioning.

Arguments

arg1 =

slot number

114