Cmc8519, Cmc8520 – Dell PowerEdge VRTX User Manual
Page 114

Recommended
Response Action
Do the following: 1) Remove the server identified in the message. 2) Restart the CMC and wait
for the CMC to complete the start up process. 3) Reinsert the server identified in the message.
If the problem persists, contact your service provider.
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
2545
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
CMC8519
Message
The LOM riser FRU for slot
arg1
FRU ID
arg2
is not functioning.
Arguments
•
arg1 =
slot number
•
arg2 =
fru id
Detailed
Description
FRU of the LOM riser specified in the message is not functioning or CMC is unable to read it.
Recommended
Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset
CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
2545
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
CMC8520
Message
The FRU on server
arg1
is not functioning.
Arguments
•
arg1 =
slot number
114