Pdr49, Pdr50 – Dell PowerEdge VRTX User Manual
Page 452

Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 3 (Informational)
Trap/EventID
4347
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR49
Message
The dedicated hot spare
arg1
is too small.
Arguments
•
arg1 =
PD Name
Detailed
Description
The dedicated hot spare is not large enough to protect all virtual disks that reside on the disk
group.
Recommended
Response Action
Assign a larger disk as the dedicated hot spare.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR50
Message
Insufficient space on the global hot spare
arg1
.
Arguments
•
arg1 =
PD Name
Detailed
Description
The global hot spare is not large enough to protect all virtual disks that reside on the controller.
452