Bat1003, Bat1004 – Dell PowerEdge VRTX User Manual
Page 73

BAT1003
Message
The battery on
arg1
learn cycle has completed.
Arguments
•
arg1 =
Controller name
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category
Storage
SubCategory
BAT = Battery Event
Severity
Severity 3 (Informational)
Trap/EventID
4275
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
BAT1004
Message
The battery on
arg1
learn cycle has timed out.
Arguments
•
arg1 =
Controller name
Detailed
Description
The controller battery must be fully charged before the learn cycle can begin. The battery may
be unable to maintain a full charge causing the learn cycle to timeout. In addition, the battery
must be able to maintain cached data for a specified period of time in the event of a power
loss. For example, some batteries maintain cached data for 24 hours. If the battery is unable to
maintain cached data for the required period of time, then the Learn cycle will timeout.
Recommended
Response Action
Replace the battery pack. The battery is unable to maintain a full charge.
Category
Storage
SubCategory
BAT = Battery Event
Severity
Severity 2 (Warning)
Trap/EventID
4274
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
73