beautypg.com

Enc19, Enc21 – Dell PowerEdge VRTX User Manual

Page 221

background image

Detailed
Description

The controller has lost communication with an Enclosure Management Module (EMM). The
cables may be loose or defective.

Recommended
Response Action

Make sure the cables are attached securely. See the storage hardware documentation for
more information on checking the cables. Reboot the system.

Category

Storage

SubCategory

ENC = Storage Enclosr

Severity

Severity 1 (Critical)

Trap/EventID

4337

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC19

Message

arg1

has failed.

Arguments

arg1 =

Enclosure Management Module Name

Detailed
Description

An Enclosure Management Module (EMM) has failed. The failure may be caused by a loss of
power to the EMM. The EMM self-test may also have identified a failure. There may also be a
firmware problem or a multi-bit error.

Recommended
Response Action

Reseat the Enclosure Management Module (EMM). See the storage hardware documentation
for information on replacing the EMM. Replace the EMM. Contact technical support if the issue
persists.

Category

Storage

SubCategory

ENC = Storage Enclosr

Severity

Severity 1 (Critical)

Trap/EventID

4337

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

ENC21

Message

arg1

has been removed.

221