Description
The controller has lost communication with an Enclosure Management Module (EMM). The
cables may be loose or defective.
Recommended
Response Action
Make sure the cables are attached securely. See the storage hardware documentation for
more information on checking the cables. Reboot the system.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC19
Message
arg1
has failed.
Arguments
•
arg1 =
Enclosure Management Module Name
Detailed
Description
An Enclosure Management Module (EMM) has failed. The failure may be caused by a loss of
power to the EMM. The EMM self-test may also have identified a failure. There may also be a
firmware problem or a multi-bit error.
Recommended
Response Action
Reseat the Enclosure Management Module (EMM). See the storage hardware documentation
for information on replacing the EMM. Replace the EMM. Contact technical support if the issue
persists.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
ENC21
Message
arg1
has been removed.