Detailed
Description
The chassis is open. System performance may be degraded, and security may be
compromised.
Recommended
Response Action
Close the chassis. Check system logs.
Category
System Health
SubCategory
SEC = Security Event
Severity
Severity 1 (Critical)
Trap/EventID
2385
LCD Message
Intrusion detected. Check chassis cover
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
SEC0040
Message
A critical stop occurred during OS load.
Detailed
Description
Operating system generated critical stop IPMI event. (Sensor type code = 20H)
Recommended
Response Action
Check video and operating system logs for additional information
Category
System Health
SubCategory
SEC = Security Event
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
SEC0041
Message
BIOS detected an error configuring the Intel Trusted Execution Technology (TXT).
Detailed
Description
TXT initialization failure. System configuration may have changed.
Recommended
Response Action
Check system hardware inventory and software configuration.