Bat1025 – Dell PowerEdge VRTX User Manual
Page 83

Detailed
Description
The battery or the battery charger is not functioning properly. The battery may have an
inadequate charge.
Recommended
Response Action
Contact technical support.
Category
Storage
SubCategory
BAT = Battery Event
Severity
Severity 2 (Warning)
Trap/EventID
4274
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
BAT1025
Message
arg1
is unable to recover cached data from the Battery Backup Unit (BBU).
Arguments
•
arg1 =
controller name
Detailed
Description
The controller was unable to recover data from the cache. This may indicate data loss has
occurred.
Recommended
Response Action
Verify that the battery is charged and in good health. See the hardware documentation for
more information. When the battery charge is unacceptably low, the battery cannot maintain
cached data. Data loss may also have occurred, restoring data from backups may be needed.
Verify whether the battery has met its recharge limit. The battery may need to be recharged.
Contact technical support if the issue persists.
Category
Storage
SubCategory
BAT = Battery Event
Severity
Severity 1 (Critical)
Trap/EventID
4273
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
83