Asr0106, Asr0107 – Dell PowerEdge VRTX User Manual
Page 65
![background image](/manuals/620821/65/background.png)
Category
System Health
SubCategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
ASR0106
Message
The OS watchdog timer expired.
Detailed
Description
The operating system or an application failed to communicate within the timeout period. No
action was taken. (IPMI sensor type code 23h - offset 00h event 3:0 - 4h)
Recommended
Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
SubCategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
ASR0107
Message
The OS watchdog timer pre-timeout interrupt was initiated.
Detailed
Description
The operating system or an application failed to respond to a pre-notification with-in the
timeout period. (IPMI sensor type code 11h - offset 07h)
Recommended
Response Action
Check the operating system, application, hardware, and system event log for exception events.
Category
System Health
SubCategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
65