Iov1008, Iov1009 – Dell PowerEdge VRTX User Manual
Page 315

Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
IOV1008
Message
Invalid Virtual Adapter FQDD
arg1
.
Arguments
•
arg1 =
FQDD value
Detailed
Description
The FQDD (Fully Qualified Device Descriptior) value entered operation does not map to any
DCIM_ChassisVAView class instance representing Virtual Adapters.
Recommended
Response Action
Perfform an Enumerate operation on the DCIM_ChassisVAView class to get the correct FQDD
for the Virtual Adaper. Retry the operation with the correct FQDD value.
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
IOV1009
Message
Mismatch in Slot or Virtual Adapter FQDD and Server Slot FQDD count.
Detailed
Description
The FQDD pairs identified in the messages do not match in the required method input
parameters.
Recommended
Response Action
Provide a valid pair of FQDDs. Please refer to the Dell Chassis PCI Management Profile
document for the required parameter definitions.
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
315