Psu0037, Psu0076 – Dell PowerEdge VRTX User Manual
Page 531

Recommended
Response Action
1) Remove and re-install the power supply. 2) Check cables and subsystem components in the
system for damage. 3) If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category
System Health
SubCategory
PSU = Power Supply
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
An over current fault detected on PSU
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PSU0037
Message
Fan failure detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
None
Recommended
Response Action
Check for fan blockage. If not replace the power supply.
Category
System Health
SubCategory
PSU = Power Supply
Severity
Severity 1 (Critical)
Trap/EventID
2185
LCD Message
Fan failure detected on PSU
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
PSU0076
Message
A power supply wattage mismatch is detected; power supply
arg1
is rated for
arg2
watts.
Arguments
•
arg1 =
number
•
arg2 =
value
531