Pst0143, Pst0192 – Dell PowerEdge VRTX User Manual
Page 504

Recommended
Response Action
Compare system memory installation to supported system memory configurations. Reduce
system configuration to minimum memory configuration.
Category
System Health
SubCategory
PST = BIOS POST
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Memory initialization error. Contact support
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
PST0143
Message
Intel Trusted Execution Technology (TXT) fatal error.
Detailed
Description
TXT boot failed. This could be related to memory errors or an error with the system TXT
configuration. A socketed TPM module may have been removed. This exception occurred early
in system power on, thus the system may not display video.
Recommended
Response Action
Check TPM presence. Remove and reapply input power. If the problem persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
PST = BIOS POST
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Intel Trusted Execution Technology (TXT) fatal error. Contact support
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
PST0192
Message
Shut-down test failed.
Detailed
Description
System BIOS shutdown test failed during POST. This exception occurred early in system power
on, thus the system may not display video. (BIOS POST exception code C0).
Recommended
Response Action
Check system event log for CMOS battery exceptions. Remove and reapply input power. If the
problem persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
504