Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8503

Message

The current value of System Input Power Cap (

arg1

AC) is less than the upper limit (

arg2

AC).

Arguments

arg1 =

power value

arg2 =

power value

Detailed
Description

This Information is provided to enable checking whether the powercap is lower than the
maximum supported powercap limit.

Recommended
Response Action

No response action is required.

Category

Audit

SubCategory

PWR = Power Usage

Severity

Severity 3 (Informational)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PWR8504

Message

Chassis power button is pressed, but the button is disabled.

Detailed
Description

The chassis power button press is detected but the button has been disabled.

Recommended
Response Action

The chassis power button is disabled. To enable the chassis power button use the CMC
RACADM command line interface, CMC Web interface. Using the command line, enter "racadm
config -g cfgChassisPower -o cfgChassisPowerButtonEnable 1". Using the Web interface, click
Chassis Overview > Power > Configuration. Clear the Disable Chassis Power Button check box.

Category

Audit