Vdr31 – Dell PowerEdge VRTX User Manual
Page 873
Arguments
•
arg1 =
virtual disk
Detailed
Description
A user changed the write policy for a virtual disk.
Recommended
Response Action
This alert is provided for informational purposes.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 3 (Informational)
Trap/EventID
4355
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
VDR31
Message
Controller cache is preserved for missing or offline
arg1
.
Arguments
•
arg1 =
VD Name
Detailed
Description
The controller is getting disconnected from its virtual disk, while Input Output (IO) is in-
progress.
Recommended
Response Action
Try importing foreign disks, if any. Check if the enclosure containing the Virtual Disk is
disconnected from the controller. Insert any disks that are reported missing or failed. If the
enclosure or disks were removed intentionally, the preserved cache can be discarded. See
storage hardware documentation for more information on performing these steps.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 2 (Warning)
Trap/EventID
4354
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
873