Pdr68, Pdr69 – Dell PowerEdge VRTX User Manual
Page 462

Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR68
Message
Dedicated spare
arg1
imported as global due to missing disk groups.
Arguments
•
arg1 =
PD Name
Detailed
Description
This alert is provided for informational purposes
Recommended
Response Action
No response action is required.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 3 (Informational)
Trap/EventID
4347
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR69
Message
Rebuild not possible on
arg1
.
Arguments
•
arg1 =
physical disk
Detailed
Description
Physical disk inserted is of the incorrect protocol. SAS or SATA mixing is not supported in the
same virtual disk.
Recommended
Response Action
Remove drive, insert correct protocol type, and force a rebuild as imposed for controller and
system.
Category
Storage
462