Pdr60, Pdr61 – Dell PowerEdge VRTX User Manual
Page 458

Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR60
Message
Error occurred on
arg1
:
arg2
.
Arguments
•
arg1 =
physical disk
•
arg2 =
error code
Detailed
Description
The reason for the error can vary depending on the situation. The firmware error code is
indicated in the message.
Recommended
Response Action
Verify the health of attached devices. Review the Lifecycle log for significant events. Replace
faulty hardware, if required. Make sure the cables are attached securely. Refer to the storage
hardware documentation for more information on checking the cable connections.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR61
Message
The rebuild of
arg1
failed due to errors on the source physical disk.
Arguments
•
arg1 =
physical disk
Detailed
Description
It is not possible to rebuild data that resides on a defective disk.
Recommended
Response Action
Replace the source disk and restore data from backup.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345