Hwc2015, Hwc5035 – Dell PowerEdge VRTX User Manual
Page 288
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
HWC2015
Message
The
arg1
is configured correctly.
Arguments
•
arg1 =
name
Detailed
Description
None.
Recommended
Response Action
No response action is required.
Category
System Health
SubCategory
HWC = Hardware Config
Severity
Severity 3 (Informational)
Trap/EventID
2331
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
HWC5035
Message
An over-temperature event detected on I/O module
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
The I/O module over heated.
Recommended
Response Action
Do the following: 1) Make sure fans are installed and working correctly. 2) Check the
temperature sensor status for the chassis and make sure it is within the chassis operating
temperature range. 3) Reseat the I/O module to clear the over-temperature condition. If the
problem persists, contact the service provider.
Category
System Health
SubCategory
HWC = Hardware Config
Severity
Severity 1 (Critical)
Trap/EventID
2329
288