Pdr98, Pdr100 – Dell PowerEdge VRTX User Manual
Page 475
![background image](/manuals/620821/475/background.png)
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 3 (Informational)
Trap/EventID
4347
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR98
Message
Command timeout occurred on
arg1
.
arg2
.
Arguments
•
arg1 =
physical disk
•
arg2 =
args
Detailed
Description
An error occurred while performing an action on the disk.
Recommended
Response Action
Check the disk is present or replace the disk.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
PDR100
Message
Dedicated Hot Spare
arg1
no longer useful for all arrays.
Arguments
•
arg1 =
PD Name
Detailed
Description
The controller is not able to communicate with a disk that is assigned as a dedicated hot spare.
The disk may have been removed. There may also be a bad or loose cable.
475