Pci1350, Pci1354 – Dell PowerEdge VRTX User Manual
Page 411

Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
PCI1350
Message
A PCI system error was detected on a component at slot
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
System performance may be degraded, or system may fail to operate.
Recommended
Response Action
Cycle input power, update component drivers, if device is removable, re-install the device.
Category
System Health
SubCategory
PCI = PCI Device
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
PCI system error on slot
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
PCI1354
Message
A bus correctable error was detected on a component at slot
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
System performance may be degraded.
Recommended
Response Action
Cycle input power, update component drivers, remove and re-install the device at the next
scheduled service time.
Category
System Health
SubCategory
PCI = PCI Device
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
411