Tmp0101, Tmp0102 – Dell PowerEdge VRTX User Manual
Page 828

Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TMP0101
Message
The system board
arg1
temperature is less than the lower critical threshold.
Arguments
•
arg1 =
name
Detailed
Description
Ambient air temperature is too cool.
Recommended
Response Action
Check system operating environment.
Category
System Health
SubCategory
TMP = Temperature
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
System board
Initial Default.
FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
TMP0102
Message
The system board
arg1
temperature is greater than the upper warning threshold.
Arguments
•
arg1 =
name
Detailed
Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended
Response Action
Check system operating environment and review event log for fan failures.
Category
System Health
SubCategory
TMP = Temperature
828