beautypg.com

Rdu0013, Rdu0014 – Dell PowerEdge VRTX User Manual

Page 640

background image

Recommended
Response Action

Check the event log for power supply failures. Review system configuration and power
consumption.

Category

System Health

SubCategory

RDU = Redundancy

Severity

Severity 1 (Critical)

Trap/EventID

2473

LCD Message

Lost PSU redundancy. Check PSU cables

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

RDU0013

Message

Power supply redundancy is degraded.

Detailed
Description

The current power operational mode is non-redundant because of a power supply exception, a
power supply inventory change, or a system power inventory change. The system was
previously operating in a power redundant mode.

Recommended
Response Action

Check the event log for power supply failures. Review system configuration and power
consumption.

Category

System Health

SubCategory

RDU = Redundancy

Severity

Severity 2 (Warning)

Trap/EventID

2474

LCD Message

PSU redundancy degraded. Check PSU cables

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

RDU0014

Message

The power supplies are not redundant.

Detailed
Description

The current power supply configuration does not meet the platform requirements to enable
redundancy. If a power supply fails the system may shut down.

Recommended
Response Action

If unintended, review system configuration and power consumption and install power supplies
accordingly. Check power supply status for failures.

Category

System Health

640