Rdu0013, Rdu0014 – Dell PowerEdge VRTX User Manual
Page 640

Recommended
Response Action
Check the event log for power supply failures. Review system configuration and power
consumption.
Category
System Health
SubCategory
RDU = Redundancy
Severity
Severity 1 (Critical)
Trap/EventID
2473
LCD Message
Lost PSU redundancy. Check PSU cables
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
RDU0013
Message
Power supply redundancy is degraded.
Detailed
Description
The current power operational mode is non-redundant because of a power supply exception, a
power supply inventory change, or a system power inventory change. The system was
previously operating in a power redundant mode.
Recommended
Response Action
Check the event log for power supply failures. Review system configuration and power
consumption.
Category
System Health
SubCategory
RDU = Redundancy
Severity
Severity 2 (Warning)
Trap/EventID
2474
LCD Message
PSU redundancy degraded. Check PSU cables
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
FALSE
RDU0014
Message
The power supplies are not redundant.
Detailed
Description
The current power supply configuration does not meet the platform requirements to enable
redundancy. If a power supply fails the system may shut down.
Recommended
Response Action
If unintended, review system configuration and power consumption and install power supplies
accordingly. Check power supply status for failures.
Category
System Health
640