beautypg.com

Tmp1001, Tmp1002 – Dell PowerEdge VRTX User Manual

Page 821

background image

Category

Storage

SubCategory

TMP = Temperature

Severity

Severity 2 (Warning)

Trap/EventID

4210

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

TMP1001

Message

arg1

has crossed the minimum warning threshold.

Arguments

arg1 =

tempsensor name

Detailed
Description

The enclosure is too cold.

Recommended
Response Action

Check whether the thermostat setting is too low and whether the room temperature is too cool.

Category

Storage

SubCategory

TMP = Temperature

Severity

Severity 2 (Warning)

Trap/EventID

4210

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

TMP1002

Message

arg1

has exceeded the maximum failure threshold.

Arguments

arg1 =

tempsensor name

Detailed
Description

The enclosure is too hot. A variety of factors can cause the excessive temperature. For
example, a fan may have failed, the thermostat may be set too high, or the room temperature
may be too hot.

821