beautypg.com

Psu8519, Psu8520 – Dell PowerEdge VRTX User Manual

Page 517

background image

Detailed
Description

The operation to read the FRU data from the PSU indentified in the message did not complete
successfully due to internal communication errors.

Recommended
Response Action

Retry the operation. If the condition persists, contact your service provider.

Category

Audit

SubCategory

PSU = Power Supply

Severity

Severity 1 (Critical)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU8519

Message

Enhanced Dynamic Power Supply Engagement (DPSE) is not supported by the current power
supply configuration and is suspended.

Detailed
Description

The Dynamic Power Supply Engagement (DPSE) feature is suspended due to the configuration
or the type of PSU present. The feature is enabled, but suspended until a supported PSU
configuration is in place.

Recommended
Response Action

Dynamic Power Supply Engagement (DPSE) is not supported by the current power supply
configuration. Verify the PSUs are supported. Replace the unsupported PSUs.

Category

Audit

SubCategory

PSU = Power Supply

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU8520

Message

Enhanced Dynamic Power Supply Engagement (DPSE) is fully supported.

Detailed
Description

The Dynamic Power Supply Enagement feature is supported and fully operational.

517