Swc8522, Swc8523 – Dell PowerEdge VRTX User Manual
Page 769
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
SWC8522
Message
Chassis Group Leader update of member
arg1
configuration successful.
Arguments
•
arg1 =
member id
Detailed
Description
Successfully completed a configuration sync with the member identified in the message.
Recommended
Response Action
No response action required.
Category
Audit
SubCategory
SWC = Software Config
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
FALSE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
FALSE
SWC8523
Message
Unable to complete Chassis Group Leader update of member
arg1
.
Arguments
•
arg1 =
DNS or IP address
Detailed
Description
Unable to complete a configuration sync with the member identified in the message.
Recommended
Response Action
Check the communications between the Chassis Group Leader and the member. Run the
RACADM command "racadm ping
communications are not functional, resolve the communications issue. If the communications
are functional, remove the member from the group and re-add the member. If the issue
persists, contact your service provider.
Category
Audit
SubCategory
SWC = Software Config
Severity
Severity 1 (Critical)
769