Vdr57, Vdr93 – Dell PowerEdge VRTX User Manual
Page 888

Detailed
Description
This message occurs if there are medium errors in the physical drives.
Recommended
Response Action
Replace the failed drives.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 1 (Critical)
Trap/EventID
4353
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
VDR57
Message
Background Initialization in
arg1
corrected medium error.
Arguments
•
arg1 =
VD Name
Detailed
Description
A disk media error was detected while the controller was completing a background task. A bad
disk block was identified. The disk block has been remapped.
Recommended
Response Action
Consider replacing the disk. If you receive this alert frequently, ensure to replace the disk. It is
recommended to routinely back up your data.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 3 (Informational)
Trap/EventID
4355
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Alert
LC Log
LCD
Power Off Power
Cycle
Reset
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
VDR93
Message
arg1
bad block medium error is cleared.
Arguments
•
arg1 =
VD Name
888