beautypg.com

Psu0007, Psu0023 – Dell PowerEdge VRTX User Manual

Page 527

background image

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

PSU0007

Message

Power supply

arg1

is operating at 110 volts, and could cause a circuit breaker fault.

Arguments

arg1 =

number

Detailed
Description

A power supply that is designed to operate at 220V, but is connected to a 110V power source
requires additional current for operation. The additional current may trip circuit-breakers or
cause other electrical issues with the input source.

Recommended
Response Action

Check input power source and cabling. Use recommended input power. Review the product
documentation. If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 2 (Warning)

Trap/EventID

FALSE

LCD Message

No LCD message display defined.

Initial Default.

FALSE

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

FALSE

PSU0023

Message

Power supply

arg1

operating at 110 volts has been acknowledged by user.

Arguments

arg1 =

number

Detailed
Description

None

Recommended
Response Action

No response action is required.

Category

System Health

SubCategory

PSU = Power Supply

Severity

Severity 3 (Informational)

527