beautypg.com

Ctl57, Ctl58 – Dell PowerEdge VRTX User Manual

Page 190

background image

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL57

Message

The factory default settings were restored on

arg1

.

Arguments

arg1 =

controller Name

Detailed
Description

The controller was reset to factory default configuration settings.

Recommended
Response Action

No response action is required.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 3 (Informational)

Trap/EventID

4331

LCD Message

No LCD message display defined.

Initial Default.

SNMP Alert;#LCD;#Remote System Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

CTL58

Message

arg1

SAS SMP communications error

arg2

Arguments

arg1 =

Controller name

arg2 =

args

Detailed
Description

The text for this alert is generated by the firmware and can vary depending on the situation.
The reference to SMP in this text refers to SAS Management Protocol.

Recommended
Response Action

There may be a SAS topology error. See the hardware documentation for information on
correct SAS topology configurations. There may be problems with the cables such as a loose
connection or an invalid cabling configuration. See the Cables Attached Correctly section for
more information on checking the cables. See the hardware documentation for information on
correct cabling configurations. Verify that the firmware version is supported.

Category

Storage

SubCategory

CTL = Storage Contr

Severity

Severity 1 (Critical)

190