beautypg.com

Sel0007, Sel0008 – Dell PowerEdge VRTX User Manual

Page 691

background image

SEL0007

Message

All event logging is enabled.

Detailed
Description

None

Recommended
Response Action

No response action is required.

Category

System Health

SubCategory

SEL = Sys Event Log

Severity

Severity 3 (Informational)

Trap/EventID

2379

LCD Message

No LCD message display defined.

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

SEL0008

Message

System event log (SEL) is full.

Detailed
Description

When the event log is full, additional events are not written to the log; or older events will be
overwritten and lost. This message may also appear if the user disabled event logging. (IPMI
sensor type code 10h - offset 04h)

Recommended
Response Action

Backup and clear log.

Category

System Health

SubCategory

SEL = Sys Event Log

Severity

Severity 1 (Critical)

Trap/EventID

2377

LCD Message

SEL is full. Review & clear log

Initial Default.

LC Log

Filter

Visibility

IPMI Alert SNMP

Alert

Email

Alert

LC Log

LCD

Power Off Power

Cycle

Reset

TRUE

FALSE

TRUE

TRUE

TRUE

FALSE

FALSE

FALSE

FALSE

691