Chapter 9: Configuring AT-CM Line Cards for Dying Gasp

234

19. If the Mode parameter is set to Passive. highlight Mode and press

Return to toggle the parameter to Active.

Note

The Admin State and the Mode parameters are the only OAM
variables you have to configure for the dying gasp feature. For
information on the other parameters in this window, refer to
“Configuring an OAM Client” on page 204.

20. Return to the Main Menu.

21. Select Configuration.

22. Select Save System and All Line Card Configurations.

23. Return to the Main Menu.

This completes the procedure for configuring the AT-CM Media Converter
Line Card for the dying gasp feature. Repeat this procedure on all of the
line cards that will send or receive the signal in the AT-CV1203 and
AT-CV5000 Chassis. Afterwards, for those line cards intended for the
AT-CV1203 Chassis, install the line cards in the units and deploy the units
at the remote sites.