Figure 47. chassis diagnostics menu, Table 13. chassis diagnostics menu – Allied Telesis AT-S99 User Manual
Page 122

Chapter 4: Configuring the AT-CV5M02 Management Card
122
Figure 46. Chassis Diagnostics Menu
The information in the Chassis Diagnostics Menu is defined in
Table 12.
Chassis Diagnostics Menu
Serial Number:A02736
MAC Address 00:0C:46:98:22:5F
CONVERTEON Chassis: AT-CV5000 AC Revision 3.0.0
Running 0 days, 1 hours, 10 minutes, 9 seconds
Current Time: 12/08/07 01:10:47
Diagnostic Results:
Flash PROM Good
Serial Interface Good
RPSA Good
Temperature:
25
C
3.3V Power:
3.2 V
5V Power:
4.9 V
12V Power:
0.0 V
Fan Status:
Good
Fan1 Speed:
3924 RPM
Fan2 Speed:
3994 RPM
RPSB Not
Present
Temperature:
25
C
3.3V Power:
0 V
5V Power:
0 V
12V Power:
0.0 V
Fan Status:
Not Present
Fan1 Speed:
Off
Fan2 Speed:
Off
Hit any key to continue ...
Table 12. Chassis Diagnostics Menu
Row
Description
Serial
Number
This field displays the serial number and hardware
revision level of the chassis.
MAC
Address
This field displays the MAC address of the backplane in
the chassis. The management card uses this address as
its MAC address when it communicates with your
network through the 10/100Base-TX port.
Converteon
Chassis
This field displays the chassis model name and revision
level, such as “AT-CV5000 Revision 1.7.”
Running
This field displays the number of hours, minutes, and
seconds since the management card was last powered
on or reset.
Current
Time
This field displays the current date and time.