Configuring the at-cm line cards – Allied Telesis AT-S99 User Manual
Page 230

Chapter 9: Configuring AT-CM Line Cards for Dying Gasp
230
Configuring the AT-CM Line Cards
This procedure explains how to configure the settings of the AT-CM Line
Cards for the dying gasp feature. The procedure has you do the following:
Verify the hardware version numbers of the line cards.
Verify the version numbers of the AT-S73 Management Software on
the line cards.
Set the operating modes of the line cards to OAM visible.
Set the OAM operating mode of the fiber optic ports on the line cards
to active.
You have to perform this procedure at a managed Converteon chassis
that has the AT-CV5M02 Management Card. The AT-CM Line Cards that
will be deployed in the unmanaged AT-CV1203 Chassis at the remote
sites have to be configured in a managed chassis before they are installed
in the AT-CV1203 Chassis.
The following procedure uses the menus to configure the line cards. You
can also perform the procedure from the web browser windows.
To verify and configure the AT-CM Line Card for the dying gasp feature
from the menus:
1. Install the AT-CM Line Card in the AT-CV5000 Chassis that has the
AT-CV5M02 Management Card.
2. Start a local management session on the chassis.
3. From the Main Menu select Administration -> Diagnostics -> Line
Card Image Version.
4. Examine the hardware version number of the AT-CM Line Card. The
version numbers are displayed as extensions of the model names, like
“-v2.” Refer to Table 27 for the supported hardware versions. Line
cards without a version number do not support the dying gasp feature.