Table 10. event log messages – Allied Telesis AT-S99 User Manual
Page 100

Chapter 4: Configuring the AT-CV5M02 Management Card
100
Table 9 lists the event messages.
Table 9. Event Log Messages
Message
Chassis
Classi-
fication
Definition
n Voltage Failed
AT-CV5000
Report
The AT-PWR14 or AT-PWR15 Power
Supply Module in the AT-CV5000 Chassis
had an output voltage failure. The variable
n can be 3.3V, 5V, or 12V and signals
which voltage failed.
Clear
The AT-PWR14 or AT-PWR15 Power
Supply Module resumed normal
operations or was replaced.
Copper port failure on
remote linecard n.
AT-CV1200
AT-CV1203
AT-CV5000
Report
The twisted pair port on a remote AT-CM
Line Card lost its link to its network
device. This message requires remote
peer management.
Clear
The twisted pair port on a remote AT-CM
Line Card established a link to its network
device. This messages requires remote
peer management.
CPM Card Reboot
AT-CV1200
AT-CV1203
AT-CV5000
Report
The AT-CV5M02 Management Card was
reset.
CV1203 Local RPS
Failure A/B
AT-CV1203
Report
One of the two external power supplies
connected to the AT-CV1203 Chassis
failed. (A failed power supply has no
detectable output voltages.) “A” and “B”
designate the power connectors on the
back panel of the chassis. This message
only appears if the AT-CV1203 Chassis
has two power supplies and just one of
the power supplies fails.
Clear
A power supply connected to the
AT-CV1203 Chassis resumed normal
operations or was replaced.